{"id":555,"date":"2010-06-17T08:17:35","date_gmt":"2010-06-17T05:17:35","guid":{"rendered":"http:\/\/www.water-simulation.com\/wsp\/?p=555"},"modified":"2014-02-16T10:29:50","modified_gmt":"2014-02-16T07:29:50","slug":"watering","status":"publish","type":"post","link":"http:\/\/www.water-simulation.com\/wsp\/2010\/06\/17\/watering\/","title":{"rendered":"WaterIng \u2013 Water Distribution System Design and Analysis"},"content":{"rendered":"<p><a title=\"WaterIng\" href=\"https:\/\/sites.google.com\/a\/ingeniousware.net\/watering\/home\">WaterIng<\/a> is a software research program of the Multidisciplinary Group of Fluid Modelling in Valencia (<a title=\"GMMF\" href=\"http:\/\/www.gmmf.upv.es\/\">GMMF<\/a>):\u05b2<\/p>\n<blockquote><p>WaterIng is a software package for water distribution system design and analysis. It offers a multi-objective evolutionary optimization engine based on distributed artificial intelligence to support design and operation decision-making (<a title=\"Agent Swarm Optimization: A multi-objective approach\" href=\"https:\/\/sites.google.com\/a\/ingeniousware.net\/watering\/project-definition#TOC-Agent-Swarm-Optimization:-A-multi-o\">Agent Swarm Optimization<\/a>). Improved solutions from both hydraulic and economic points of view can be implemented, profiting from the high flexibility of WaterIng platform for defining and evaluating objectives. Different rule-based agents can be incorporated to perform search of solutions more efficiently; depending on the characteristics of the problem, agent population size may vary automatically. WaterIng makes it possible to manage water network data easily by using <em>TableView<\/em>; additionally, a useful visualization of networks elements over a GIS-based <em>MapView<\/em>is done. It is possible to import shapefiles, information contained in EPANET files (.INP), or simply copy and paste information from Excel tables to <em>Tableview<\/em>. Design solutions or existent systems can by analyzed in steady state flow including extended period simulation.\u05b2<\/p><\/blockquote>\n<p style=\"text-align: center;\"><a href=\"http:\/\/www.water-simulation.com\/wsp\/wp-content\/uploads\/2010\/06\/WaterIng.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-558 aligncenter\" title=\"WaterIng\" alt=\"Water Distribution System Design and Analysis\" src=\"http:\/\/www.water-simulation.com\/wsp\/wp-content\/uploads\/2010\/06\/WaterIng-300x157.jpg\" width=\"300\" height=\"157\" \/><\/a>\u05b2<\/p>\n<p>I have downloaded the program and installed it (you will need the Microsoft .NET framework 3.5 and some VC++ 2008 redistributable files). Unfortunately I was not able to run the program and I kept getting an error messages while trying to start a new project. Searching the WaterIng website I found a few screenshots of the Hanoi water network which\u05b2\u00a0is a well known <a title=\"Hanoi Water Distribution Network \" href=\"http:\/\/centres.exeter.ac.uk\/cws\/benchmarks\/layout\/37-hanoi-water-distribution-network\">benchmark<\/a>\u05b2\u00a0optimization problem.\u05b2<\/p>\n<div id=\"attachment_565\" style=\"width: 310px\" class=\"wp-caption aligncenter\"><a href=\"http:\/\/www.water-simulation.com\/wsp\/wp-content\/uploads\/2010\/06\/Hano-Network.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-565\" class=\"size-medium wp-image-565\" title=\"Hano-Network\" alt=\"\" src=\"http:\/\/www.water-simulation.com\/wsp\/wp-content\/uploads\/2010\/06\/Hano-Network-300x182.jpg\" width=\"300\" height=\"182\" \/><\/a><p id=\"caption-attachment-565\" class=\"wp-caption-text\">WaterIng &#8211; Hanoi Water Distribution Network<\/p><\/div>\n<p>The WaterIng team used it to demonstrate the program optimization capabilities. It is not explicitly written but from the following image, showing a pareto front,\u05b2\u00a0I understand that the two optimization objectives were: minimum cost (horizontal axes) and minimum\u05b2\u00a0head deviation.\u05b2<\/p>\n<div id=\"attachment_567\" style=\"width: 516px\" class=\"wp-caption aligncenter\"><a href=\"http:\/\/www.water-simulation.com\/wsp\/wp-content\/uploads\/2010\/06\/Pareto-front.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-567\" class=\"size-full wp-image-567 \" title=\"Pareto-front\" alt=\"\" src=\"http:\/\/www.water-simulation.com\/wsp\/wp-content\/uploads\/2010\/06\/Pareto-front.jpg\" width=\"506\" height=\"248\" \/><\/a><p id=\"caption-attachment-567\" class=\"wp-caption-text\">Hanoi water network optimization &#8211; pareto front<\/p><\/div>\n<p>One can see that on the very right hand side the cost values are around 6,100,000 with little or no head deviations. This value is in the range of previous published results.<\/p>\n<p><strong>Update:<\/strong> a limited version of WaterIng is available over at <a href=\"http:\/\/www.ingeniousware.com\/\">http:\/\/www.ingeniousware.com<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>WaterIng is a software research program of the Multidisciplinary Group of Fluid Modelling in Valencia (GMMF):\u05b2 WaterIng is a software package for water distribution system design and analysis. It offers a multi-objective evolutionary optimization engine based on distributed artificial intelligence &hellip;<\/p>\n<p class=\"read-more\"> <a class=\"\" href=\"http:\/\/www.water-simulation.com\/wsp\/2010\/06\/17\/watering\/\"> <span class=\"screen-reader-text\">WaterIng \u2013 Water Distribution System Design and Analysis<\/span> Read More &raquo;<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[8,2],"tags":[92,94,90,91,93,89],"class_list":["post-555","post","type-post","status-publish","format-standard","hentry","category-epanet-related","category-water-simulation-packages","tag-agent-swarm","tag-aso","tag-gmmf","tag-hanoi","tag-optimization","tag-watering"],"_links":{"self":[{"href":"http:\/\/www.water-simulation.com\/wsp\/wp-json\/wp\/v2\/posts\/555","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.water-simulation.com\/wsp\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.water-simulation.com\/wsp\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.water-simulation.com\/wsp\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.water-simulation.com\/wsp\/wp-json\/wp\/v2\/comments?post=555"}],"version-history":[{"count":2,"href":"http:\/\/www.water-simulation.com\/wsp\/wp-json\/wp\/v2\/posts\/555\/revisions"}],"predecessor-version":[{"id":1262,"href":"http:\/\/www.water-simulation.com\/wsp\/wp-json\/wp\/v2\/posts\/555\/revisions\/1262"}],"wp:attachment":[{"href":"http:\/\/www.water-simulation.com\/wsp\/wp-json\/wp\/v2\/media?parent=555"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.water-simulation.com\/wsp\/wp-json\/wp\/v2\/categories?post=555"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.water-simulation.com\/wsp\/wp-json\/wp\/v2\/tags?post=555"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}